1.It can measure liquid, gas and vapor, especially for the flow measurement with small flow rate and low Reynolds number, it has more unique advantages than other flow meters.
2.Lower pressure loss, generally is 4~9kpa, higher is 20kpa.
3.There is a wide flow range, generally is 10:1, the special design flow range can be extended.
4.The factory calibration adopts the method of 11 sections calibration, and the precision of the product reaches 1.0 grade.
5.It can select card sleeve connection, piping φ6mm、φ8mm、φ10mm、φ12mm. Flange connections can also be selected and the flange standard is determined according to user requirements.
6.It can measure liquid, gas and vapor (minimum measurable flow is 0.3L/h), especially for the flow measurement with small flow rate and low Reynolds number, it has more unique advantages than other flow meters.
7.Max pressure is 69Mpa
Main Parameters
Output Signal: Two-wire 4~20 mADC current output and load HART protocol communication
Flange Standard: HG/T20592、HG/T20615 DN15 1.6MPa or on request
Power Supply Inlet: M12×1.5(Female Thread) or on request
Max Medium Pressure: ≤69MPa
Accuracy: Standard: 4.0 grade; Special: 2.5 grade
Turndown: 10:1
Medium Temperature: -40℃≤T≤300℃
Ambient Temperature: -25℃≤T≤70℃
Explosion-proof Type: Ex iaⅡ C T4
IP Rating: IP65
Measurement Range
Water: 0.3 L/H~120L/H(20℃)
Air: 1.2 L/H~3600L/H(0.1013MPa, 20℃)
Suitable Medium Viscosity: η<5mPa.s
Refining: Catalytic Reforming, Acid-Containing Sedimentation Tank
Natural Gas: Sulfur Recovery, Light Hydrocarbon Recovery
您的浏览器当前宽度低于1100px;请使用1300px以上宽度访问。